For OEMs

The same panel, run after run.

Your engineering stays yours. We check the parts list every time it's quoted, so a part going away doesn't stop a run.

Photo: a row of identical machine control panels, labeled and ready to ship

Working with us

The same bill of material, checked again on the current run.

Parts Check (sample), lines 1–5 of 10

PanelConveyor control panel, repeat order
Quantity2 panels
Supply480 V 3-phase 3-wire 60 Hz
Control voltage120 V AC
Short-circuit rating (SCCR)10 kA at 480 V
The assembly SCCR is confirmed by the build shop.
LineTagQty / panelTotalPart numberDescriptionFlagAlternate
1 Main breaker 1 2 Siemens 3VA5110-4EC31-0AA0 Siemens 3VA51 UL molded case circuit breaker, 3-pole, 100 A, TM230 FTAM (fixed thermal, adjustable magnetic), UL type SEAS, without wire connectorsLug / terminal kit: not included Lead timePotential lead time issue based on stock levels · checked 2026-10-30Published short-circuit rating on its own: 25 kA at 480 V ABB XT1HU3100AFF000XXXNearest available, differs on interrupting rating (higher)equivalent for your team to approve, see A1
2 CV1, CV2 reversing contactors 2 4 Schneider Electric (Square D) LC2D18G7 Schneider Electric TeSys Deca reversing contactor (mechanically interlocked, pre-wired), 3-pole (3 NO), 18 A AC-3, 32 A AC-1, coil 120 V AC 50/60 Hz, screw terminals Lead timePotential lead time issue based on stock levels · checked 2026-10-30Not offered as build-from-parts: Schneider Electric publishes a reversing wiring kit for LC1D18G7 (LAD9R1, LAD9R1V, LAD9V5), but its UL listing is not confirmed in the catalog — the build-from-parts path is not offered Allen-Bradley 104-C23D22Nearest available, differs on coil voltage and type (wider range), AC-3 rating (higher), hp 3-phase 480 V (higher), hp 3-phase 600 V (higher) and 1 moreequivalent for your team to approve, see A2Stock not published
3 CV1, CV2 overloads 2 4 Schneider Electric (Square D) LR3D14 Schneider Electric TeSys Deca thermal overload relay (ambient compensated, bimetallic), 7–10 A, Class 10, without single-phase sensitivity (for single-phase or DC loads), direct mounting to LC1/LC2 D09–D38 Lead timePotential lead time issue based on stock levels · checked 2026-10-30 ABB T16-7.6Nearest available, differs on adjustment range (wider range), phase-loss sensitivityequivalent for your team to approve, see A3
4 Spare reversing contactor 1 2 Eaton XTCR025C21A Eaton XT IEC reversing contactor (factory assembled) XTCR025C21A, frame C, 3-pole, 2 NO + 1 NC each contactor aux, coil 110 V 50 Hz / 120 V 60 Hz, screw terminals Lead timePotential lead time issue based on stock levels · checked 2026-10-30Not offered as build-from-parts: no reversing wiring kit is published for this contactor in the catalog. Allen-Bradley 104-C30D22
+ Allen-Bradley 100-SA10Nearest available, differs on AC-3 rating (higher), hp 3-phase 480 V (higher), hp 3-phase 600 V (higher), auxiliary contact arrangementequivalent for your team to approve, see A4Stock not published
5 CV3 conveyor drive 1 2 Siemens 6SL3210-5BE21-5UV0 Siemens SINAMICS V20 basic converter 6SL3210-5BE21-5UV0, 1.5 kW / 2 hp, IL 4.1/4.1 A, IH 4.1/4.1 A, 380…480 V 3-phase AC, frame FSA, without integrated line filterdiscontinued Discontinueddiscontinued; Siemens publishes 6SL3210-5BE21-5UV1 as the successor Siemens 6SL3210-5BE21-5UV1published successor, see A5Lead time: Potential lead time issue based on stock levels
A1 · line 1 · Main breaker
Siemens 3VA5110-4EC31-0AA0 → ABB XT1HU3100AFF000XXX

ABB SACE Tmax XT1H molded case circuit breaker, 3-pole, 100 A, TMF/TMD thermal-magnetic trip unit, 80% rated, 65 kA @ 480 V AC, front terminals (F)

Nearest available, differs on interrupting rating (higher). No exact match was found; this one needs your approval.

Matched (yours → alternate): Kind of product: circuit breaker · Poles: 3 · Trip curve / trip unit: thermal-magnetic · Trip rating: 100 A · Interrupting rating: 25 kA @480 V / 25 kA @480Y/277 V → 100 kA @240 V / 65 kA @480 V / 25 kA @600Y/347 V / 50 kA @250 V DC (2 poles in series) (covers yours) · Fixed vs adjustable trip: fixed trip

Confirm on the catalog data:

  • interrupting rating at your voltage
  • combination / series ratings
  • frame size and panel space — fit not compared

Other candidates, nearest first: Schneider Electric BGL36100; ABB XT1SU3100AFF000XXX; Schneider Electric BJL36100, HGL36100, HGL36100C, HJL36100; and three others further above your ratings. Each also covers your part on every rating compared; the further down the list, the further above your ratings it sits. Schneider Electric BGL36100 and ABB XT1SU3100AFF000XXX sit nearer your ratings, but the stock check did not show enough of them. Schneider Electric BJL36100 is tied with XT1HU3100AFF000XXX on every rating compared. They differ in details we did not compare (options, versions or ratings not on file), so check the one you prefer before approving it instead.

A2 · line 2 · CV1, CV2 reversing contactors
Schneider Electric (Square D) LC2D18G7 → Allen-Bradley 104-C23D22

Allen-Bradley 104-C reversing contactor (factory assembled, mechanical/electrical interlock), 3-pole (3 NO main), 23 A AC-3, 32 A AC-1, 1 NO + 1 NC aux per contactor, coil 110 V AC 50 Hz / 120 V AC 60 Hz

Nearest available, differs on coil voltage and type (wider range), AC-3 rating (higher), hp 3-phase 480 V (higher), hp 3-phase 600 V (higher) and 1 more. No exact match was found; this one needs your approval.

Matched (yours → alternate): Kind of product: general purpose contactor · Poles: 3 · Reversing / non-reversing: reversing · Coil voltage and type: works at your 120 V AC control voltage (yours 120 V AC 50/60 Hz → this one 110 V AC 50 Hz / 120 V AC 60 Hz) · Duty: general · Enclosed / open: open · AC-3 rating: 18 A → 23 A (covers yours) · hp 3-phase 480 V: 10 hp → 15 hp (covers yours) · hp 3-phase 600 V: 15 hp → 20 hp (covers yours) · hp 3-phase 240 V: 5 hp → 7.5 hp (covers yours) · hp 3-phase 208 V: 5 hp · Rated voltage: 600 V · AC-1 / thermal current rating: 32 A · Auxiliary contact arrangement: both 1 NO + 1 NC

Differs from your part:

  • larger frame: 23 A vs 18 A (IEC AC-3 rating at 400 V); 15 hp vs 10 hp at 480 V

Confirm on the catalog data:

  • SCCR of the combination with its upstream protective device
  • the overload relay that mounts on it
  • frame width and mounting of your accessories — fit not compared
A3 · line 3 · CV1, CV2 overloads
Schneider Electric (Square D) LR3D14 → ABB T16-7.6

ABB T16 thermal overload relay, 5.70…7.60 A

Nearest available, differs on adjustment range (wider range), phase-loss sensitivity. No exact match was found; this one needs your approval.

Matched (yours → alternate): Kind of product: overload relay · Reset type: manual/automatic · Trip class: 10 · Setting range covers your motor FLA 7.6 A: 5.7–7.6 A

Differs from your part:

  • Phase-loss sensitivity: yours not sensitive → this one we haven't confirmed it against ABB's catalog page — confirm before substituting
  • Adjustment range (vs yours): yours 7–10 → this one 5.7–7.6

Confirm on the catalog data:

  • mounting to the contactor
  • SCCR of the combination it is used in

Other candidates, nearest first: ABB TF42-7.6. ABB TF42-7.6 is tied with T16-7.6 on every rating compared. They differ in details we did not compare (options, versions or ratings not on file), so check the one you prefer before approving it instead.

A4 · line 4 · Spare reversing contactor
Eaton XTCR025C21A → Allen-Bradley 104-C30D22 + Allen-Bradley 100-SA10

Allen-Bradley 104-C reversing contactor (factory assembled, mechanical/electrical interlock), 3-pole (3 NO main), 30 A AC-3, 65 A AC-1, 1 NO + 1 NC aux per contactor, coil 110 V AC 50 Hz / 120 V AC 60 Hz
100-SA10: Allen-Bradley 100-C side-mounted auxiliary contact block — two-way numbering for left or right mounting, electronic-compatible down to 17 V / 10 mA, mirror contact to the main poles, 1 NO, without sequence terminal designations

Nearest available, differs on AC-3 rating (higher), hp 3-phase 480 V (higher), hp 3-phase 600 V (higher), auxiliary contact arrangement. No exact match was found; this one needs your approval.

Matched (yours → alternate): Kind of product: general purpose contactor · Poles: 3 · Reversing / non-reversing: reversing · Coil voltage and type: 110 V 50 Hz / 120 V 60 Hz → 110 V AC 50 Hz / 120 V AC 60 Hz (covers yours) · Duty: general · Enclosed / open: open · AC-3 rating: 25 A → 30 A (covers yours) · hp 3-phase 480 V: 15 hp → 20 hp (covers yours) · hp 3-phase 600 V: 20 hp → 25 hp (covers yours) · hp 3-phase 240 V: 10 hp · hp 3-phase 208 V: 7.5 hp · Rated voltage: 600 V

Differs from your part:

  • built-in 1 NO + 1 NC aux per contactor vs your 2 NO + 1 NC each contactor — add 100-SA10 (1 NO auxiliary contact block) to match yours (also published as fitting: 100-SB10)

Confirm on the catalog data:

  • ac-1 / thermal current rating
  • SCCR of the combination with its upstream protective device
  • the overload relay that mounts on it
  • frame width and mounting of your accessories — fit not compared

Other candidates, nearest first: Allen-Bradley 104-C30D02. Each also covers your part on every rating compared; the further down the list, the further above your ratings it sits. They differ in details we did not compare (options, versions or ratings not on file), so check the one you prefer before approving it instead.

A5 · line 5 · CV3 conveyor drive
Siemens 6SL3210-5BE21-5UV0 → Siemens 6SL3210-5BE21-5UV1

Siemens SINAMICS V20 basic converter 6SL3210-5BE21-5UV1, 1.5 kW / 2 hp, IL 4.1/4.1 A, IH 4.1/4.1 A, 380…480 V 3-phase AC, frame FSA, without integrated line filter

Siemens publishes this as the successor to your part.

Matched (yours → alternate): published by Siemens as the replacement · UL listing not confirmed from the catalog

Send the list before your next run.

Request a quote Check part numbers